The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.

Wang QY, Zheng YF

Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China.

OBJECTIVES: The aim of this study was to investigate the electrochemical behavior of Ti50Ni47.2Co2.8 alloy in deaerated artificial saliva solutions with binary NiTi alloy as reference and to characterize the composition and structure of the passive film after polarization tests. METHODS: The corrosion behavior of NiTiCo alloy was systematically studied by open circuit potential, potentiodynamic and potentiostatic techniques. The surface characterization after anodic polarization tests were demonstrated by XPS. The electrolytes were maintained at 37 degrees C by immersing the test cell in water bath. 500 mV vs. SCE was applied on the samples for potentiostatic tests. The metal ions concentration was measured by ICP/OES. RESULTS: Potentiodynamic and potentiostatic tests results showed that the corrosion behavior of NiTiCo was similar to that of NiTi alloy. With the increase of pH value of the electrolytes, both corrosion potential (Ecorr) and pitting corrosion potential (Eb) decreased. XPS results revealed that the outmost passive film consisted mainly of TiO2 which were identical with that of NiTi alloy. The Ni ion release amount of NiTiCo was very close to that of NiTi alloy as examined by ICP/OES. Neither Ti nor Co ion was detected due to the detection limitation. SIGNIFICANCE: The corresponding relationship between corrosion behavior and pH value of the artificial saliva should be taken into consideration during the application of orthodontic wires. The addition of Co had little effect on the corrosion behavior of NiTi as well as the formation of the passive film.

Published 22 July 2008 in Dent Mater, 24(9): 1207-11.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Orthodontic Research Today. All Rights Reserved.



Orthodontic Research Today Archive:

Volume 1 (2005)
  Issue 1 (March)
  Issue 2 (April)
  Issue 3 (May)
  Issue 4 (June)
  Issue 5 (July)
  Issue 6 (August)
  Issue 7 (September)
  Issue 8 (October)
  Issue 9 (November)
  Issue 10 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)



Orthodontic Books

An Evaluation of Orthodontic Practice Management Software: Maximizing the Return on the Investment of the Orthodontist

An Evaluation of Orthodontic Practice Management Software: Maximizing the Return on the Investment of the Orthodontist