Orthodontic Research - Braces, Retainers, Treatment

Orthodontic Research Today is a free monthly online journal that collates and summarizes the latest research about Orthodontic, including details on braces, retainers, treatment.


Orthodontic Research Today

Home

View Latest Issue

Information About Orthodontic

Books on Orthodontic

Advertising in Research Today

View Other Research Today Publications



Thermal analysis of as-received and clinically retrieved copper-nickel-titanium orthodontic archwires.

Biermann MC, Berzins DW, Bradley TG

Department of Developmental Sciences, Marquette University, Milwaukee, WI 53201-1881, USA.

OBJECTIVE: To compare as-received copper-nickel-titanium (CuNiTi) archwires to those used in patients by means of differential scanning calorimetry (DSC). Also, the thermal or phase properties of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi archwires were studied to ascertain if their properties match those indicated by the manufacturer. MATERIALS AND METHODS: Six wires of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi were tested as-received, and six each of the 27 degrees C and 35 degrees C wires were examined after use in patients for an average of approximately 9 and 7 weeks, respectively. Segments of archwire were investigated by DSC over the temperature range from -100 degrees C to 150 degrees C at 10 degrees C per minute. RESULTS: There were no significant differences between as-received and clinically used 27 degrees C and 35 degrees C wires for all parameters (heating onset, endset, and enthalpy and cooling onset, endset, and enthalpy), except the 27 degrees C wires exhibited a significant decrease in the heating enthalpy associated with the martensite-to-austenite transition after clinical use. The heating endsets (austenite finish temperatures) of the 27 degrees C and 35 degrees C wires were within 2 degrees C of those claimed by the manufacturer, but the 40 degrees C wires were found to be nearer to 36 degrees C than 40 degrees C. CONCLUSIONS: Clinical use of CuNiTi wires resulted in few differences when compared with as-received wires analyzed by DSC. Two temperature varieties of CuNiTi are reasonably within the parameters of those identified by the manufacturer.

Published 30 April 2007 in Angle Orthod, 77(3): 499-503.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Orthodontic Research Today. All Rights Reserved.



Orthodontic Research Today Archive:

Volume 1 (2005)
  Issue 1 (March)
  Issue 2 (April)
  Issue 3 (May)
  Issue 4 (June)
  Issue 5 (July)
  Issue 6 (August)
  Issue 7 (September)
  Issue 8 (October)
  Issue 9 (November)
  Issue 10 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Orthodontic Books

Contemporary Orthodontics e-dition: Text with Continually Updated Online Reference

Contemporary Orthodontics e-dition: Text with Continually Updated Online Reference