Orthodontic Research - Braces, Retainers, Treatment

Orthodontic Research Today is a free monthly online journal that collates and summarizes the latest research about Orthodontic, including details on braces, retainers, treatment.


Orthodontic Research Today

Home

View Latest Issue

Information About Orthodontic

Books on Orthodontic

Advertising in Research Today

View Other Research Today Publications



Parameters Affecting Primary Stability of Orthodontic Mini-implants.

Wilmes B, Rademacher C, Olthoff G, Drescher D

Department of Orthodontics, Heinrich-Heine-Universität Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Germany, wilmes@med.uni-duesseldorf.de.

AIM: Treatment options in orthodontics have been expanded by skeletal anchorage via mini-implants over the last few years. Sufficient primary stability is imperative to minimize implant loss rate. The aim of this study was to quantitatively analyze the factors influencing primary stability: bone quality, implant-design, diameter, and depth of pilot drilling. MATERIAL AND METHODS: Thirty-six pelvic bone segments (ilium) of country pigs were dissected and embedded in resin. To determine the primary stability, we measured the insertion torque of five different mini-implant types (tomas((R))-pin [Dentaurum, Ispringen, Germany] 08 and 10 mm, and Dual Top [Jeil Medical Corporation, Seoul, Korea] 1.6 x 8 and 10 mm plus 2 x 10 mm). Twenty-five or 30 implants were inserted into each pelvic bone segment following preparation of the implant sites using pilot drill diameters of 1.0, 1.1, 1.2 and 1.3 mm and pilot drill depths of 1, 2, 3, 6 and 10 mm. Five implants were inserted for reference purposes to establish comparability. Thicknesses of bone compacta were measured via micro-computer tomography. RESULTS: Insertion torques of orthodontic mini-implants and therefore primary stability varied greatly, depending on bone quality, implant-design, and preparation of implant site. Compared with the tomas((R))-pin, the Dual Top screw showed significantlygreater primary stability. Torque moments beyond 230 Nmm caused fractures of 9 Dual Top screws. CONCLUSION: Compacta thickness, implant design and implant site preparation have a strong impact on the primary stability of mini-implants for orthodontic anchorage. Depending on the insertion site and local bone quality, the clinician should choose an optimum combination of implant and pilot-drilling diameter and depth.

Published 31 May 2006 in J Orofac Orthop, 67(3): 162-174.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Orthodontic Research Today. All Rights Reserved.



Orthodontic Research Today Archive:

Volume 1 (2005)
  Issue 1 (March)
  Issue 2 (April)
  Issue 3 (May)
  Issue 4 (June)
  Issue 5 (July)
  Issue 6 (August)
  Issue 7 (September)
  Issue 8 (October)
  Issue 9 (November)
  Issue 10 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)



Orthodontic Books

Orthodontics and Paediatric Denistry: Colour Guide (Colour Guides)

Orthodontics and Paediatric Denistry: Colour Guide (Colour Guides)