Orthodontic Research - Braces, Retainers, Treatment

Orthodontic Research Today is a free monthly online journal that collates and summarizes the latest research about Orthodontic, including details on braces, retainers, treatment.


Orthodontic Research Today

Home

View Latest Issue

Information About Orthodontic

Books on Orthodontic

Advertising in Research Today

View Other Research Today Publications



Magnetic field interactions of orthodontic wires during magnetic resonance imaging (MRI) at 1.5 Tesla.

Klocke A, Kemper J, Schulze D, Adam G, Kahl-Nieke B

Department of Orthodontics, University Hospital Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany. klocke@uke.uni-hamburg.de

BACKGROUND: Orthodontic appliances pose a potential risk during magnetic resonance imaging (MRI) due to forces on metallic objects within the static magnetic field of MRI systems. The aim of the present investigation was to measure forces on orthodontic wires caused by the static magnetic field of a 1.5-Tesla MRI system, and to assess the safety hazards associated with these forces. MATERIALS AND METHODS: Thirty-two different orthodontic wires (21 arch wires, eight ligature wires and three retainer wires) were investigated in a 1.5-Tesla MRI system (Magnetom Symphony, Siemens Medical Solutions, Erlangen, Germany). The translational forces were measured using the deflection angle test (ASTM F2052-02); rotational forces were assessed on a 5-point qualitative scale. RESULTS AND CONCLUSION: All retainer wires and the steel arch wires (the Noninium arch wire being the exception) were subjected to considerable rotational and translational forces within the MRI system's magnetic field. Translational forces were from 9.1- to 27.6-times as high as gravitational forces on these objects. Steel ligature wires and arch wires made of cobalt chromium, titanium molybdenum, nickel-titanium, and brass alloys showed no or negligible forces within the magnetic field. The translational and rotational forces within the MRI magnetic field should pose no risk to carefully-ligated arch wires. Steel retainer wire bonds should be checked to ensure secure attachment prior to an MRI investigation.

Published 26 July 2005 in J Orofac Orthop, 66(4): 279-87.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Orthodontic Research Today. All Rights Reserved.



Orthodontic Research Today Archive:

Volume 1 (2005)
  Issue 1 (March)
  Issue 2 (April)
  Issue 3 (May)
  Issue 4 (June)
  Issue 5 (July)
  Issue 6 (August)
  Issue 7 (September)
  Issue 8 (October)
  Issue 9 (November)
  Issue 10 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Orthodontic Books

Textbook of Orthodontics

Textbook of Orthodontics